You will need
to demonstrate Building regulation compliance by a Window Energy Rating OR by
the U value method
|
|
VERSION
3.1 (October '11)
|
|
Alternatively, in a statement issued by FENSA, any
window installation featuring:
|
|
|
|
|
• Soft coat low E glass, argon and a warm
edge spacer
or
|
|
• Hard
coat low E glass, argon, warm edge spacer & low iron glass
|
|
will deem
the window as compliant, without any further evidence. Proof of the installed IGU configuration
|
will be required, however this method will mean a
higher than necessary Liniar spec. window is installed.
|
|
|
|
Product
Specification
|
Foiled
product reinforcement guidelines as per white profiles
|
Indicative
U-value
|
|
|
|
Step 1:
|
Define the profile suite & specification
|
|
Bead:
Internally glazed specifications
|
Building
Regulation compliance level 1.6 or less
|
|
Select Suite:
|
|
|
Liniar has partnered with
Build-Check to incorporate our product range within the Oracle U-Value
Calculator. Available through the Liniar website homepage, the resulting headed certificate can be
printed for presentation to FENSA or
Building Control to demonstrate compliance.
|
|
Profile Spec:
|
|
|
Optional
Specification:
|
|
|
|
|
Step 2:
|
Define the IGU (Glazing) configuration
|
|
|
|
Thermal
Transmittance
|
|
Select IGU specification:
|
|
|
IGU Config:
|
|
(Indicative U - value)
|
|
W/(m2·K)
|
|
Select Outer Pane:
|
|
Product Ref:
|
|
There is a small annual charge for unlimited
use of The Oracle, this is
payable directly to Build Check, contact Frances on 01494 452713.
|
|
|
|
Emissivity:
|
|
(Low E glass)
|
|
Select Gas Fill:
|
|
|
Gas content:
|
|
|
|
Glazing Supplier:
|
|
Centre Pane:
|
|
W/(m2·K)
|
Indicative
WER Ratings
|
|
|
Step 3:
|
Define the Spacer Bar specification within the IGU
|
|
|
Building
Regulation compliance level 'C' or above
|
|
Select Spacer Bar:
|
|
|
Supplier:
|
|
To install an energy rated window
the fabricator/supplier will need to
register their windows with an approved Window Energy Rating Scheme.
|
|
|
Sightline:
|
|
|
|
|
|
|
WER Ratings Calculation
|
Sample Window
Style 'L1' : 1.23m wide x 1.48m high
|
Energy Index
|
WER
|
|
Climate zone
|
UK
|
kWh/(m2·yr)
|
Band Rating
|
|
WER Energy
index
|
218.6 gwindow - 68.5 x (Uwindow + Effective L50)
|
|
|
|
Solar factor
|
gwindow
|
|
|
|
|
|
Window air leakage
heat loss
|
Effective L50
|
|
W/(m2·K)
|
|
|
|
Thermal
transmittance
|
Uwindow
|
|
W/(m2·K)
|
If your company/window is not
registered with an approved Window Energy Ratings Scheme, the window may only
be sold and installed under the self certifying U-value method (check thermal
transmittance above).
|
|
|
|
|
|
We are pleased to announce that output results generated by
this calculator have been verified and approved by an auditor from the
British Frenestration Ratings Council
|